Before you hit “buy,” check out these 148 specs & features — including real-world favorites like general information, power & electrical output, engine & fuel system & performance & efficiency. It’s the kind of detail pros care about.
A fast snapshot of the KOHLER 48RCLC, covering its standout specification and what you can expect right out of the box.
KOHLER 48RCLC
The KOHLER 48RCLC provides 48,000 watts of industrial-grade power with Fast Response X™ technology, utilizing a rare-earth permanent magnet excitation system to deliver superior voltage stability for sensitive business and home systems.
Specifications & Facts
148
Specs measured. Drama avoided.
Not just numbers on a box. We looked at how the KOHLER 48RCLC actually performs with specs like general information, power & electrical output, engine & fuel system & performance & efficiency and others that users rely on daily.
General Information
13
KOHLER 48RCLC
Start Method
How do you start the generator?
0
KOHLER 48RCLC
0
Votes
Electric Start, Remote Start
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Start methods listed are Electric Start and Remote Start.
These options provide convenient local start and the ability to start the generator remotely for automated or unattended operation.
Describes how the generator is started.
Don’t keep it to yourself — be the first to react and review the
Start Method on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Phase Type
What phase type does it support?
0
KOHLER 48RCLC
0
Votes
Three-Phase
generator in this range
Who knows?
(Help us out by suggesting one!)
Indicates whether the generator outputs single-phase or three-phase power.
Don’t keep it to yourself — be the first to react and review the
Phase Type on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Electrical Frequency
What is the electrical frequency?
60
Hz
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
Specifies the operating electrical frequency of the generator output.
Don’t keep it to yourself — be the first to react and review the
Electrical Frequency on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Certification Standards
What certifications does it have?
0
KOHLER 48RCLC
0
Votes
EPA
generator in this range
Who knows?
(Help us out by suggesting one!)
Lists major compliance or certification standards met by the generator.
Don’t keep it to yourself — be the first to react and review the
Certification Standards on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Product Type
What type of generator is this?
0
KOHLER 48RCLC
0
Votes
Standby Generator
generator in this range
Who knows?
(Help us out by suggesting one!)
Identifies the general product classification of the generator.
Don’t keep it to yourself — be the first to react and review the
Product Type on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Generator Category
What category does this generator belong to?
0
KOHLER 48RCLC
0
Votes
Commercial
generator in this range
Who knows?
(Help us out by suggesting one!)
Defines the primary market segment the generator is designed for.
Don’t keep it to yourself — be the first to react and review the
Generator Category on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Power Output Class
What is the power output class?
0
KOHLER 48RCLC
0
Votes
High Power
generator in this range
Who knows?
(Help us out by suggesting one!)
Groups the generator based on its general power capacity range.
Don’t keep it to yourself — be the first to react and review the
Power Output Class on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Intended Use
What is this generator intended for?
0
KOHLER 48RCLC
0
Votes
Home Backup, Emergency Power
generator in this range
Who knows?
(Help us out by suggesting one!)
Describes the typical use scenarios the generator is designed for.
Don’t keep it to yourself — be the first to react and review the
Intended Use on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Portability Type
How portable is the generator?
0
KOHLER 48RCLC
0
Votes
Stationary
generator in this range
Who knows?
(Help us out by suggesting one!)
Defines how the generator is moved or positioned.
Don’t keep it to yourself — be the first to react and review the
Portability Type on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Installation Type
What installation type does it require?
0
KOHLER 48RCLC
0
Votes
Permanent
generator in this range
Who knows?
(Help us out by suggesting one!)
Indicates whether the generator is meant for temporary or fixed installation.
Don’t keep it to yourself — be the first to react and review the
Installation Type on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Cooling Method
How is the generator cooled?
0
KOHLER 48RCLC
0
Votes
Liquid-Cooled
generator in this range
Who knows?
(Help us out by suggesting one!)
Explains how the generator engine is cooled during operation.
Don’t keep it to yourself — be the first to react and review the
Cooling Method on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Country of Manufacture
Where is it made?
0
KOHLER 48RCLC
0
Votes
USA
generator in this range
Who knows?
(Help us out by suggesting one!)
Indicates where the generator is manufactured.
Don’t keep it to yourself — be the first to react and review the
Country of Manufacture on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Release Year
When was it released?
0
KOHLER 48RCLC
0
Votes
2019
generator in this range
Who knows?
(Help us out by suggesting one!)
Shows the year the generator model was released.
Don’t keep it to yourself — be the first to react and review the
Release Year on KOHLER 48RCLC
◉ and help others decide!
Power & Electrical Output
15
KOHLER 48RCLC
Voltage Output
What voltage does it output?
240
Volt
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Nominal voltage output is 240Volt.
This is suitable for 240V loads and typical transfer switch arrangements for larger standby applications.
Specifies the electrical voltage produced by the generator.
Don’t keep it to yourself — be the first to react and review the
Voltage Output on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Running Wattage
What is the running wattage?
48,000
Watt
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Rated running wattage is 48000Watt.
This indicates the continuous electrical output available for sustained loads.
The continuous amount of power the generator can supply during normal operation without interruption.
Don’t keep it to yourself — be the first to react and review the
Running Wattage on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Starting Wattage
What is the starting wattage?
48,000
Watt
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Starting wattage is 48000Watt.
A starting wattage equal to the running wattage suggests no additional short-term surge capacity is claimed.
The maximum surge power available to start appliances or equipment with high initial power demand.
Don’t keep it to yourself — be the first to react and review the
Starting Wattage on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Amperage Output
What is the amperage output?
200
Amp
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Maximum amperage output is 200Amp.
Use this to calculate maximum concurrent load at the rated voltage.
Indicates the maximum current the generator can supply.
Don’t keep it to yourself — be the first to react and review the
Amperage Output on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Surge Handling Capability
How much surge can it handle?
48,000
Watt
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Surge handling capability is 48000Watt.
Matching surge and running values implies the unit is specified for steady high-capacity use rather than brief overloads.
Describes how well the generator manages sudden power surges.
Don’t keep it to yourself — be the first to react and review the
Surge Handling Capability on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Total Harmonic Distortion (THD)
What is the THD level?
5
%
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
Don’t keep it to yourself — be the first to react and review the
Total Harmonic Distortion (THD) on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Power Stability Rating
How stable is the power output?
0
KOHLER 48RCLC
0
Votes
Standard
generator in this range
Who knows?
(Help us out by suggesting one!)
Qualitative assessment of output consistency.
Don’t keep it to yourself — be the first to react and review the
Power Stability Rating on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Outlet Types
What outlet types are included?
0
KOHLER 48RCLC
0
Votes
240V
generator in this range
Who knows?
(Help us out by suggesting one!)
Describes the types of electrical outlets supported.
Don’t keep it to yourself — be the first to react and review the
Outlet Types on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
DC Output
Does it support DC output?
No
0Votes
KOHLER 48RCLC
generator in this range
Who knows?
(Help us out by suggesting one!)
Indicates whether the generator provides DC power output.
Don’t keep it to yourself — be the first to react and review the
DC Output on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
USB Output
Are USB outputs included?
No
0Votes
KOHLER 48RCLC
generator in this range
Who knows?
(Help us out by suggesting one!)
Shows if USB ports are available for small devices.
Don’t keep it to yourself — be the first to react and review the
USB Output on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Parallel Capability
Can it run in parallel?
No
0Votes
KOHLER 48RCLC
generator in this range
Who knows?
(Help us out by suggesting one!)
Allows multiple generators to be connected together for more power.
Don’t keep it to yourself — be the first to react and review the
Parallel Capability on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Automatic Voltage Regulation
Does it regulate voltage automatically?
Yes
0Votes
KOHLER 48RCLC
generator in this range
Who knows?
(Help us out by suggesting one!)
Maintains consistent voltage under varying loads.
Don’t keep it to yourself — be the first to react and review the
Automatic Voltage Regulation on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Power Factor
What is the power factor level?
0
KOHLER 48RCLC
0
Votes
Standard
generator in this range
Who knows?
(Help us out by suggesting one!)
Indicates the efficiency of power delivery from the generator to connected loads, expressed as a qualitative performance level rather than a numeric ratio.
Don’t keep it to yourself — be the first to react and review the
Power Factor on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Continuous Load Capacity
What continuous load can it handle?
100
%
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
The percentage of load the generator can handle continuously.
Don’t keep it to yourself — be the first to react and review the
Continuous Load Capacity on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Inverter Technology
Does it use inverter technology?
No
0Votes
KOHLER 48RCLC
generator in this range
Who knows?
(Help us out by suggesting one!)
Indicates whether inverter-based power generation is used.
Don’t keep it to yourself — be the first to react and review the
Inverter Technology on KOHLER 48RCLC
◉ and help others decide!
Engine & Fuel System
12
KOHLER 48RCLC
Displacement
What is the engine displacement?
6,208
cc
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Engine displacement is 6208cc.
Higher displacement typically provides greater torque for heavy load starts and sustained demand.
Measures the engine’s cylinder volume, influencing power potential.
Don’t keep it to yourself — be the first to react and review the
Displacement on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Fuel Type
What fuel does it use?
0
KOHLER 48RCLC
0
Votes
Natural Gas, Propane
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Supported fuel types are Natural Gas and Propane.
Having both Natural Gas and Propane options allows flexibility for use with municipal gas supplies or bottled LPG.
Specifies the type of fuel the generator operates on.
Don’t keep it to yourself — be the first to react and review the
Fuel Type on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Oil Capacity
How much oil does it hold?
5
qt
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Oil capacity is 5 qt, which converts to 4.73 L.
Ensure the correct oil volume when performing service to avoid over- or under-filling the crankcase.
Shows how much oil the engine requires.
Don’t keep it to yourself — be the first to react and review the
Oil Capacity on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Engine Type
What type of engine does it use?
0
KOHLER 48RCLC
0
Votes
OHV
generator in this range
Who knows?
(Help us out by suggesting one!)
Defines the mechanical engine design used to generate power.
Don’t keep it to yourself — be the first to react and review the
Engine Type on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Engine Brand Type
What engine brand type is used?
0
KOHLER 48RCLC
0
Votes
OEM
generator in this range
Who knows?
(Help us out by suggesting one!)
Indicates whether the engine is in-house or externally sourced.
Don’t keep it to yourself — be the first to react and review the
Engine Brand Type on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Number of Cylinders
How many cylinders does it have?
0
KOHLER 48RCLC
0
Votes
4
generator in this range
Who knows?
(Help us out by suggesting one!)
States how many cylinders the engine has.
Don’t keep it to yourself — be the first to react and review the
Number of Cylinders on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Runtime Performance
How is the runtime performance?
0
KOHLER 48RCLC
0
Votes
Long
generator in this range
Who knows?
(Help us out by suggesting one!)
Describes the generator’s overall operating duration on a full fuel tank across typical load conditions, expressed as a qualitative runtime level.
Don’t keep it to yourself — be the first to react and review the
Runtime Performance on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Carburetor Type
What carburetor type is included?
0
KOHLER 48RCLC
0
Votes
Standard
generator in this range
Who knows?
(Help us out by suggesting one!)
Describes the carburetor configuration used.
Don’t keep it to yourself — be the first to react and review the
Carburetor Type on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Fuel Injection Type
Is it carbureted or fuel injected?
0
KOHLER 48RCLC
0
Votes
Electronic Fuel Injection
generator in this range
Who knows?
(Help us out by suggesting one!)
Indicates how fuel is delivered to the engine.
Don’t keep it to yourself — be the first to react and review the
Fuel Injection Type on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Oil Type
What oil type is recommended?
0
KOHLER 48RCLC
0
Votes
SAE 5W-30
generator in this range
Who knows?
(Help us out by suggesting one!)
Specifies the recommended engine oil type.
Don’t keep it to yourself — be the first to react and review the
Oil Type on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Low Oil Shutdown
Does it have low-oil shutdown?
Yes
0Votes
KOHLER 48RCLC
generator in this range
Who knows?
(Help us out by suggesting one!)
Automatically shuts down the engine if oil is low.
Don’t keep it to yourself — be the first to react and review the
Low Oil Shutdown on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Fuel Gauge
Is there a fuel gauge?
No
0Votes
KOHLER 48RCLC
generator in this range
Who knows?
(Help us out by suggesting one!)
Displays the current fuel level in the tank.
Don’t keep it to yourself — be the first to react and review the
Fuel Gauge on KOHLER 48RCLC
◉ and help others decide!
Performance & Efficiency
12
KOHLER 48RCLC
Load Response Time
How fast does it respond to load changes?
10
sec
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Load response time is 10sec.
This is the time expected for the generator to stabilize voltage under a changing load.
Time taken to stabilize output when load changes suddenly.
Don’t keep it to yourself — be the first to react and review the
Load Response Time on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Voltage Stability Under Load
How stable is voltage under load?
0
KOHLER 48RCLC
0
Votes
Good
generator in this range
Who knows?
(Help us out by suggesting one!)
Indicates how well voltage remains steady under varying loads.
Don’t keep it to yourself — be the first to react and review the
Voltage Stability Under Load on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Fuel Efficiency Rating
How fuel-efficient is the generator?
0
KOHLER 48RCLC
0
Votes
High
generator in this range
Who knows?
(Help us out by suggesting one!)
Overall assessment of how efficiently fuel is converted into power.
Don’t keep it to yourself — be the first to react and review the
Fuel Efficiency Rating on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Frequency Stability
How stable is the frequency output?
0
KOHLER 48RCLC
0
Votes
Precision
generator in this range
Who knows?
(Help us out by suggesting one!)
Measures consistency of output frequency during operation.
Don’t keep it to yourself — be the first to react and review the
Frequency Stability on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Power to Weight Ratio
What is the power-to-weight ratio?
96
Watt
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
Compares power output relative to generator weight.
Don’t keep it to yourself — be the first to react and review the
Power to Weight Ratio on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Eco Mode
Does the generator have eco mode?
No
0Votes
KOHLER 48RCLC
generator in this range
Who knows?
(Help us out by suggesting one!)
Automatically adjusts engine speed based on power demand to improve fuel efficiency, reduce noise, and extend runtime during low-load operation.
Don’t keep it to yourself — be the first to react and review the
Eco Mode on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Thermal Efficiency
What is the thermal efficiency?
30
%
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
Indicates how well heat energy is converted into mechanical power.
Don’t keep it to yourself — be the first to react and review the
Thermal Efficiency on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Energy Conversion Type
What energy conversion type is used?
0
KOHLER 48RCLC
0
Votes
Electromechanical
generator in this range
Who knows?
(Help us out by suggesting one!)
Describes how energy is converted into electricity.
Don’t keep it to yourself — be the first to react and review the
Energy Conversion Type on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Overload Recovery Time
How quickly does it recover from overload?
2
sec
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
Time required to recover normal output after overload.
Don’t keep it to yourself — be the first to react and review the
Overload Recovery Time on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Start Reliability Rating
How reliable is starting?
0
KOHLER 48RCLC
0
Votes
Excellent
generator in this range
Who knows?
(Help us out by suggesting one!)
Likelihood of successful starts under normal conditions.
Don’t keep it to yourself — be the first to react and review the
Start Reliability Rating on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Cold Start Performance
How does it perform in cold starts?
0
KOHLER 48RCLC
0
Votes
Enhanced
generator in this range
Who knows?
(Help us out by suggesting one!)
Indicates ease of starting in low temperatures.
Don’t keep it to yourself — be the first to react and review the
Cold Start Performance on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Altitude Performance Rating
How does it perform at altitude?
0
KOHLER 48RCLC
0
Votes
Sea Level
generator in this range
Who knows?
(Help us out by suggesting one!)
Describes performance effectiveness at higher elevations.
Don’t keep it to yourself — be the first to react and review the
Altitude Performance Rating on KOHLER 48RCLC
◉ and help others decide!
Noise & Emissions
11
KOHLER 48RCLC
Noise Level
What is the noise level of the generator?
61
dB
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Measured noise level is 61dB.
While moderate for a commercial generator, hearing protection is advised for prolonged close exposure.
Measures the generator’s operating noise output in decibels, representing how loud the unit is during normal operation.
Don’t keep it to yourself — be the first to react and review the
Noise Level on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Sound Insulation Type
What sound insulation is used?
0
KOHLER 48RCLC
0
Votes
Full Enclosure
generator in this range
Who knows?
(Help us out by suggesting one!)
Describes built-in noise dampening materials or design.
Don’t keep it to yourself — be the first to react and review the
Sound Insulation Type on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Muffler Type
What type of muffler does it have?
0
KOHLER 48RCLC
0
Votes
Low-Noise
generator in this range
Who knows?
(Help us out by suggesting one!)
Identifies the exhaust muffler design.
Don’t keep it to yourself — be the first to react and review the
Muffler Type on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Emission Compliance
Is it emission compliant?
0
KOHLER 48RCLC
0
Votes
EPA
generator in this range
Who knows?
(Help us out by suggesting one!)
Indicates regulatory emission standards met.
Don’t keep it to yourself — be the first to react and review the
Emission Compliance on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Exhaust Orientation
Where is the exhaust directed?
0
KOHLER 48RCLC
0
Votes
Rear
generator in this range
Who knows?
(Help us out by suggesting one!)
Shows the direction exhaust gases are expelled.
Don’t keep it to yourself — be the first to react and review the
Exhaust Orientation on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Carbon Monoxide Detection
Does it detect carbon monoxide?
No
0Votes
KOHLER 48RCLC
generator in this range
Who knows?
(Help us out by suggesting one!)
Detects dangerous CO levels during operation.
Don’t keep it to yourself — be the first to react and review the
Carbon Monoxide Detection on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
CO Auto Shutdown
Does it shut down for CO safety?
No
0Votes
KOHLER 48RCLC
generator in this range
Who knows?
(Help us out by suggesting one!)
Automatically shuts down if CO reaches unsafe levels.
Don’t keep it to yourself — be the first to react and review the
CO Auto Shutdown on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Emission Control System
What emission control system is used?
0
KOHLER 48RCLC
0
Votes
Electronic Control
generator in this range
Who knows?
(Help us out by suggesting one!)
Describes systems used to reduce emissions.
Don’t keep it to yourself — be the first to react and review the
Emission Control System on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Smoke Level Rating
How much smoke does it produce?
0
KOHLER 48RCLC
0
Votes
Low
generator in this range
Who knows?
(Help us out by suggesting one!)
Qualitative measure of visible exhaust smoke.
Don’t keep it to yourself — be the first to react and review the
Smoke Level Rating on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Environmental Compliance
What environmental rules does it meet?
0
KOHLER 48RCLC
0
Votes
Federal
generator in this range
Who knows?
(Help us out by suggesting one!)
Indicates level of environmental regulation compliance.
Don’t keep it to yourself — be the first to react and review the
Environmental Compliance on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Indoor Use Approval
Is it approved for indoor use?
No
0Votes
KOHLER 48RCLC
generator in this range
Who knows?
(Help us out by suggesting one!)
Indicates if the generator is approved for indoor use.
Don’t keep it to yourself — be the first to react and review the
Indoor Use Approval on KOHLER 48RCLC
◉ and help others decide!
Dimensions & Weight
11
KOHLER 48RCLC
Width
What is the width of the generator?
89.8
inch
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Unit width is 89.8 inch, converting to 228.09 cm.
Width is important for doorway access and placement on installation pads.
Measures the overall width of the generator body.
Don’t keep it to yourself — be the first to react and review the
Width on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Depth
What is the depth of the generator?
32.9
inch
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Unit depth is 32.9 inch, which converts to 83.57 cm.
Depth is useful for planning clearances in tight mechanical rooms or transport packaging.
Measures the front-to-back depth of the generator.
Don’t keep it to yourself — be the first to react and review the
Depth on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Height
What is the height of the generator?
46.5
inch
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Unit height is 46.5 inch, which converts to 118.11 cm.
Use this height for siting under overhangs or inside enclosures.
Measures the overall height of the generator.
Don’t keep it to yourself — be the first to react and review the
Height on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Weight
How much does the generator weigh?
1,690
lbs
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Unit weight is 1690 lbs, equivalent to 766.39 kg.
Knowing the weight is important for lifting, transportation and foundation design.
Indicates how heavy the generator is without fuel.
Don’t keep it to yourself — be the first to react and review the
Weight on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Ground Clearance
What is the ground clearance?
3
inch
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Ground clearance is 3 inch and converts to 7.62 cm.
This affects placement on uneven surfaces and clearance for mounting hardware.
Distance between the base and ground surface.
Don’t keep it to yourself — be the first to react and review the
Ground Clearance on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Footprint Area
How much floor space does it need?
7.5
sq ft
0Votes
generator in this range
Who knows?
(Help us out by suggesting one!)
KOHLER 48RCLC
Footprint area is 7.5 sq ft, which converts to 0.697 m².
Use this when planning placement and clearance on concrete pads or within equipment rooms.
Total ground area occupied by the generator.
Don’t keep it to yourself — be the first to react and review the
Footprint Area on KOHLER 48RCLC
◉ and help others decide!
KOHLER 48RCLC
Center of Gravity Design
How stable is the generator design?
0
KOHLER 48RCLC
0
Votes
Low
generator in this range
Who knows?
(Help us out by suggesting one!)